Power up screen Showing version number
and discharge amps |
| |
|
 |
Main menu showing type of cells
to charge, use key 6 to toggle between Li-Po and Ni-Mh cells |
| |
|
 |
Press key 1 to display and set the
charge voltage change over point. ie the voltage at which the charge will
change from Constant Current (CC) to Constant Voltage (CV) Use the *
and # keys to increase or decrease the value. Please consult your
cell supplier for this information. Pressing the 0 key will step to the
next screen where you can set the voltage for 2 cells.
From information received a CV value of 4.2
volts for a single cell and
8.4 volts for 2 cells will charge the cells close to full capacity. |
| |
|
 |
Step the voltage up or down using the
* and # keys, press key 0 to exit.
|
| |
|
 |
Press key 5 to set the charge current
(normally 1C, where C equals the capacity of the cells to be
charged) The pack is charged at this current until the change-over
voltage is reached. Press key 0 when the correct current
is set to display the next screen. |
| |
|
 |
The Cut-off amps is the point at which
charging is terminated.
ie When charging the pack voltage will increase,
when the voltage of the pack reaches the change over voltage (8 volts in
this case) the charge is changed from CC to CV. To maintain the
constant voltage the charge current has to be reduced slowly, when the
current reaches the value set for the cutoff amps the charge is
terminated. Press key 0 to exit.
From tests we have found no real advantage in
setting a low Cutoff amps, set this value to 2 amps. |
| |
|
 |
Pressing and holding down key 1 will
start charge, Pro-Trak will test the voltage of the pack and
configure the charge for 1 cell or 2 cells automatically. |
| |
|
 |
When Pro-Trak has finished checking
for the number of cells it will display the information shown here.
Charging 2 Li-Po cells with Constant Current
to 8 volt then Constant Voltage.
|
| |
|
 |
Charge
screen showing from top left to top right:-
Power supply voltage - Pack
Voltage - Change-over voltage
From bottom left to bottom right
Charge time - Charge
Current - Charge capacity
|
| |
|
 |
If using Pro-Trak to discharge,
the cut-off volts can be set by pressing key 9. Please consult your
cell supplier about discharging Li-Po cells. |
| |
|
| |
|
|
The graph below is from tests we
were doing on a single Li-Po cell.
The change over voltage was set at 4.2 volts and the cut-off amps was set
to 0.5
You can see when the pack voltage reached the change over volts the charge
current started to reduce.
When the current fell to 0.5 charge was terminated. |
|

|
| |
|