1.
New key 8 test function for Li-Po/Li-Fe
2. New Charge routine.
3. Displayed
information after charge complete.
4. Program Charge current
and Cut-off amps
5. Program Voltage cut-off
6. Program Test facility
1. New key 8 test
function for Li-Po/Li-Fe
| Press and hold key 8 to start pack test | |
| Pro-Trak will ramp the charge current
to that set for charging but with a maximum of 5 amps.
i.e. if charge current is set for 3 amps the current is ramped to 3 amps, if the charge current is set for more than 5 amps Pro-Trak will ramp to 5 amps. Pro-Trak displays the pack voltage charge current and calculated charge state |
|
| If the charge state is less than 100%
then Pro-Trak will indicate the pack is not charged. If voltage cut-off is set to > 8.4 volts then the following rule is applied. If the current reaches the programmed charge
current before the pack reaches the voltage cut-off, the pack is
considered not charged. |
|
| If the charge state is equal to or
more than 100% the pack is considered charged and Pack Charged is displayed. If voltage cut-off is set to > 8.4 volts then the following rule is applied. If charge current reaches the programmed voltage cut-off before the charge current is reached the pack is considered charged. The recommended voltage cut-off is 8.4 volts for 2 Li-Po cells. |
|
| If the remote lead is fitted the display will show the charge state of the pack and each cell | |
| If the charge state is less than 100%
then Pro-Trak will indicate the pack is not charged. If voltage cut-off is set to > 8.4 volts then the following rule is applied. If the current reaches the programmed charge
current before the pack reaches the voltage cut-off, the pack is
considered not charged. |
|
| If the charge state is equal to or
more than 100% the pack is considered charged and Pack Charged is displayed If voltage cut-off is set to > 8.4 volts then the following rule is applied. If charge current reaches the programmed voltage cut-off before the charge current is reached the pack is considered charged. The recommended voltage cut-off is 8.4 volts for 2 Li-Po cells. |
|
2. New Charge routine (Back
to Top)
| Press key 0 to go through the charge
menu to start charge or Press and hold key 1 to start charge. Pro-Trak goes through the procedure described above to determine the charge state of the pack. If the charge state is equal to or more than 100% the pack is considered charged and charge is aborted. If the charge state is less than 100% then charge is commenced. |
|
| During the checking stage Pro-Trak
automatically determines the number of cells to charge and the state of
charge. If charge is to be commenced then Pro-Trak displays the charge
details. The display shows:- CCCV Constant current constant voltage charge L Linear charge ( charge type can be changed in setup menu*) 8.40Po Charging to 8.4 volts Cell type Li-Po** Cells 2 Number of cells to charge 5.00 A Charge current 5.00 amps * Charge type can be changed to Soft Pulse, Hard Pulse ,Linear or Re-Pulse. ** Uses charge parameters for cell type displayed. Only linear charge is recommended for Lithium cells |
|
| The main charge screen is then
displayed.
13.25 Input supply from power unit. |
|
| If the remote lead is fitted to the center
tap of the pack the top right display shows the difference in voltage
between the 2 cells. If the difference in voltage is more than 0.05 a
audible warning is given every 60 seconds. The default value of 0.05 can be changed in the set-up menu under Set Li Warn. You can also change:- |
|
| 3. Displayed information after charge complete. (Back to Top)
|
4. Program Charge Current and Cut-off amps (Back to Top)
| When main menu is displayed press key 5 to set the charge current. | |
| Scroll the current up using the # key
and down using the * key.
Pro-Trak can be programmed to charge at 12 amps, however charging a single li-pi or li-fe cell will consume a lot of power. Pro-Trak is limited to 120 watts of power. While charging Pro-Trak monitors the wattage and will adjust the charge current to achieve the maximum charge current without exceeding 120 watts.!!
|
|
| After setting the charge current the
cut-off current is programmed. Scroll the current up using the # key and down using the * key. |
|
5. Program Voltage cut-off (Back to Top)
| When the main Menu is displayed press key 1 to set voltage cutoff | |
| Set the voltage cutoff for single cell
Scroll the voltage up or down using # and * keys Press key 0 to step to next screen. |
|
| Set the voltage cutoff for two cells
Scroll the voltage up or down using # and * keys Press key 0 to step to accept.
|
|
6. Program Test facility (Back to Top)
| When in main menu scroll down to Setup using the # key. | |
| Press key 0 to enter setup menu. | |
| The setup menu is displayed.
Use the # key to scroll down to Set Test Amps |
|
| Press key 0 to enter menu. | |
| Scroll the Test amps to the required
value and press 0.
Test amps is a value between the charge amps and the cutoff amps at which the charge input capacity is recorded. See details in 3 above. |
|
| Scroll the display to YES or NO using
the # key.
If set to NO the information in 3 above is not displayed. |
|