Main Menu:- ( if you get lost! holding key 7 down will return to this Main Menu)

>CHARGE

Type of charge:- Peak, Temperature, Part Charge, etc

  DISCHARGE

Discharge

  CYCLE CELLS

Cycle Pack once or a number of times

  SETUP

Set-up Menu temperature cut-off, turbo set-up etc

  MOTOR RUN-IN

Use with run-in assembly to run in motors

  PRINT

Sends data to serial printer

Press the # key a number of times until the cursor points to Set-up. Press the * key a number of times to return the cursor to Charge. This scrolling allows you to select one of the above functions.

Using the scroll keys ( # or * ) you can select the function required. (if held down the key will auto repeat). Pressing the 0 key when the cursor is pointing at a function, will select that function or take you to another menu for the function selected.

Press key 0 when the cursor is pointing at >Charge, this will take you to the charge menu.

Charge Menu

> Peak Detect   (1)

Charge is terminated by peak detection

  Repeak           (2)

Charge is terminated by peak detection. Use to re-peak

  Temp Detect   (3)

Charge is terminated by temperature detection

  Push Charge    (4)

Charge is terminated by peak detection,   set rest times before repeak

  Part Charge     (5)

Use to part charge Ni-Mh cells for storage

  Pack Test        (6)

Charges at 6 amps for 20 seconds to identify faulty cells

  Tx Charge

Emergency transmitter charge

(1), (2), (3), (4), (5), and (6), indicate hot keys that can be used to start charge from main menu

Scroll to Peak Detect using the * or # scroll keys and press the "0" enter key. This will take you to menus where you can select battery type (Ni-Mh or Ni-Cd) scroll to the required type with the scroll keys and press"0". Then select the charge type (see below) using scroll keys, when the required type has been selected press key "0". You will then have to select whether to discharge the pack before charging, scroll to "yes" or "no" and press "0"

The display will show the parameters you have chosen to charge the pack. The unit indicates the charge current by bleeping, 4 bleeps indicates 4 or 4.5 amps 5 bleeps indicates 5 or 5.5 amps.

Profile Charge

Linear charge until pack reaches 9 volts then switches over to Repulse charge.

Linear Charge

Constant current charge

Soft pulse

Linear charge that includes a rest period of 50 mS every 250mS.

Repulse Charge

Linear charge that includes a discharge pulse. Do not use this method on fully discharged cells

After a short period the display will show the following.

12.34

9.34

0.00

 

Input

Pack

Delta

00:04

4.50

6

 

Time

Amps

Capacity

With the remote leads fitted Pro-Trak does not show input supply volts

 

Note

As you go through the charge menu the settings are stored in  HOT keys to save you having to run through the menu 
every time you wish to charge a pack.

From the Main Menu where the cursor is pointing to charge (>Charge) pressing and holding certain keys will start charge.

Holding down key 1 will start Peak charge using the settings you selected while going through the charge menu

Holding down key 2 will start Re-Peak charge using the settings you selected while going through the Re-Peak charge menu

Holding down key 3 will start Temperature charge using the settings you selected while going through the Temperature charge menu

Holding down key 4 will start Push charge  using the settings you selected while going through Push charge menu

Holding down key 5 will start Part Charge 

Holding down key 6 will start Pack test 

If you wish to change something ( lets say you wish to change from Linear to Profile charge in peak detect ) simply go through the charge menu and 
change from Linear to Profile. Run through the rest of the menu and start charge.  The new settings are now stored in Hot key 1

 