Pressing key 4 will take you to the View menu. Use the scroll keys to scroll through the menu.
| >Time | Run time charging/discharging |
| Pack Volts | Voltage of pack (real time) |
| Peak Volts | Highest voltage reached by pack during charge |
| Fallback | Calculated fallback voltage of pack (peak minus end volts) |
| End volts | Voltage of pack at switch off |
| Ave 1 Volts | Average volts during discharge over Ave1 time **** see below |
| Ave 2 Volts | Average volts over the complete discharge time |
| Pack 5 min | Pack voltage at Ave1 time. |
| C/Capacity | Charge capacity of pack calculated at end of charge. |
| D/Capacity | Discharge capacity calculated at the end of discharge |
| K/Joules | K/Joules of pack calculated at end of discharge |
| Power % | Calculated power (punch) of the pack, 100 % being a club pack. |
| Pack Match | Calculated from cell end volts after discharge |
| Pack Assessment | Displays Pack match and worst cell. |
| Pro1 RT | Temperature of Probe 1 in Real Time. |
| Pro1 Charg | Temperature of Probe 1 at the end of charge. |
| **** | ( Ave1 time can be set from 1 to 9 minutes and is programmed in set-up menu) |
Use the scroll keys (# and * ) to step the cursor to Pack Volts, press the 0 key to display voltages of all 6 cells.
|
Cell 1 |
Cell 2 |
Cell 3 |
|
1.34 |
1.35 |
1.29 |
|
1.35 |
1.33 |
1.35 |
|
Cell 4 |
Cell 5 |
Cell 6 |
Press key 0 to return to view menu, press key 4 to return to Time Volts Amps display. While charging keys 4 and 0 are used to view information. Key 7 is held down to abort charging. While charging /discharging pressing and holding key 7 will abort and return you to the main menu. Press key "5" to change current while charging.
Key 1 delta volts
Press key 1 to set the DELTA VOLTS. Use the
scroll keys to increase or decrease the Delta voltage. When you have selected
the value required press the 0 key to enter the value. The default value is
0.18volts.
Pressing key 1 while charging will allow you to change the delta while the pack
is charging.
When a pack is being charged the voltage across
it increases until it reaches the fully charged state. At this point the voltage
begins to drop, this voltage drop is referred to as the negative delta voltage.
When the pack voltage falls by the amount programmed in the DELTA VOLTS charging
is stopped. The higher the voltage set in DELTA VOLTS the warmer the pack will
be before switch off.
Press and hold key 1 to start Peak Charge (only from Main
Menu)
Key 2 auto start/switch fan on if charging in progress
Press key 2 to set an AUTOMATIC START TIME. The delay can be scrolled up or down using the scroll keys then entered by pressing the 0 key. Now run through the charge menus selecting the type of charge required and press 0 to start charge. The display will show the delay time counting down, when the timer reaches zero charging will be started.
While charging is in progress pressing key 2 will switch the fan on, overriding the temperature sensor fitted to the heatsink. The temperature sensor will switch the fan on automatically when the temperature of the heatsink is above 50° C. The operation of the fan during charge can be set as permanently ON or OFF. If set to OFF the fan is controlled by the temperature sensor. If set to ON the fan is switched on as soon as charging is started.
Press and hold key 2 to start Repeak Charge. (only from Main Menu)
| Back to Contents | Next Page >> | Home |