Pressing key 4 will take you to the view menu . All data in the View Menu is pack data.
|
Pack Data |
||
|
>Time |
31:29 |
|
|
Pack Volt |
7.23 |
Pressing the 0 key will display the selected |
|
Peak Volt |
7.23 |
data of all 6 cells. Pressing 0 again will return |
|
Fallback |
0.24 |
to the View Menu. |
|
End Volts |
5.34 |
|
|
Ave 1 Volts |
7.12 |
|
|
Ave 2 Volts |
6.56 |
|
|
Pack 5 min |
6.49 |
|
|
C/Capacity |
2361 |
|
|
D/Capacity |
2012 |
|
|
K/Joules |
53.33 |
|
|
Power % |
101% |
|
|
Pack Match |
97% |
See Pack Match |
|
Pack Assessment |
Displays the Pack match and the worst cell |
|
|
Pro1 RT |
38`C |
Temperature of probe 1 in real time |
|
Pro1 Charg |
35`C |
Pack Test charges at 6 amps for 20 seconds, this highlights possible faulty cells
Pack must be discharged first
1 Connect remote leads to flat battery pack.
2 Select Pack Test from the charge menu.
3 Press 0 to start Pack test.
4 Pro-Trak will display the voltage of all 6 cells.
5 After 15 seconds the voltage is latched into the display
|
Cell 1 |
Cell 2 |
Cell 3 |
Good packs are those that have all cell voltages approximately the same This would indicate a good pack of batteries |
|
1.54 |
1.57 |
1.57 |
|
|
1.55 |
1.54 |
1.55 |
|
|
Cell 4 |
Cell 5 |
Cell6 |
|
Cell 1 |
Cell 2 |
Cell 3 |
This is not a good pack cells 1,3 and 5 are suspect |
|
1.75 |
1.59 |
1.87 |
|
|
1.55 |
1.94 |
1.55 |
|
|
Cell 4 |
Cell 5 |
Cell6 |
Used with our run-in assembly to run-in new brushes. Pressing key 0 while running will toggle between pulse run-in and linear run-in. If the voltage to the motor during linear run-in exceeds 6 volts, pulse run-in will be automatically re-selected
You must use our motor run-in assembly and a 12 battery or 25 amp power supply unit to use Pulsed Run-In facility correctly.
| Back to Contents | Next Page >> | Home |